如何解决七段显示输出未知
我正在尝试创建一个从0到9的计数器,并在我的Nexys A7的七段显示器上显示。代码可以编译,但是在测试台中它表明所有输出都是未知的。我测试了我的时钟分频器模块,看起来不错。我不确定为什么它不起作用。
module BCD_sevenseg(
input clk,output segA,segB,segC,segD,segE,segF,segG,segDP,div_clk
);
counter module1(
.clk(clk),.div_clk(div_clk)
);
reg[3:0] BCD; //BCD signal is 4 bits wide
always@(posedge clk) //check every positive edge
if(div_clk) //executes if counter value from module1 is true
BCD <= (BCD == 4'h9 ? //check if BCD is at binary 9
4'h0 : BCD + 4'h1 );
//true: reset to 0
//false: count up
reg [7:0] sevenseg; //8 segments on 7 segment display (w/ decimal point)
always@(*)
case(BCD) //one case for each digit
4'h0: sevenseg = 8'b11111100;
4'h1: sevenseg = 8'b01100000;
4'h2: sevenseg = 8'b11011010;
4'h3: sevenseg = 8'b11110010;
4'h4: sevenseg = 8'b01100110;
4'h5: sevenseg = 8'b10110110;
4'h6: sevenseg = 8'b10111110;
4'h7: sevenseg = 8'b11100000;
4'h8: sevenseg = 8'b11111110;
4'h9: sevenseg = 8'b11110110;
default: sevenseg = 8'b00000000;
endcase
assign {segA,segDP} = sevenseg;
endmodule
时钟分频器:
module counter(
input clk,output reg div_clk=0
);
integer count_value=0;
always@(posedge clk)
begin
if(count_value == 10)//change this number to adjust output signal frequency
begin
div_clk = ~div_clk;
count_value <= 0;
end
else
count_value <= count_value+1;
end
endmodule
测试平台代码:
module BCD_sevenseg_tb();
reg clk=0;
wire segA,div_clk;
BCD_sevenseg UUT(
.clk(clk),.segA(segA),.segB(segB),.segC(segC),.segD(segD),.segE(segE),.segF(segF),.segG(segG),.segDP(segDP),.div_clk(div_clk)
);
always
#1 clk=~clk;
endmodule
解决方法
您的输出始终为X,因为BCD
始终为X。您将BCD
声明为reg
,默认为X。您需要将BCD
初始化为已知的值,例如0。
出于仿真目的,您可以使用以下方法轻松完成此操作:
reg[3:0] BCD = 0; //BCD signal is 4 bits wide
初始化信号的标准方法是使用复位输入信号。例如:
always @(posedge clk) begin
if (reset) begin
BCD <= 4'h0;
end else begin
if (div_clk) BCD <= (BCD == 4'h9 ? 4'h0 : BCD + 4'h1 );
end
end